A containerized incinerator with design suitable for use in remote area specifically the oil and gas industry.Incinerator unit should be able to handle common waste with ability to accept small amounts of medical waste,Primary chamber should provide operating temp minimum of 850C; secondary chamber should operate at 1200C with minimum of 2sec residence time.The container shall be fitted with checker plate flooring, fluorescent lighting, complete electrical and safety equipment. Automatic temperature control ON / OFF Operation. PLC Based control panel, digital temperature control. Audio visual alarm system for burner lockout and overload fault, Primary and secondary chamber temperature controllers/indicators, auto controls. electrical control switches, push buttons, relays, contactors, thermocouples, burner sequence controllers, emergency stop, timers, and alarms.
Recent Posts
- Diesel Oil Deposit Oil Tank 3m3 for Waste Incinerator
- Containerized Industrial Waste Incinerators
- Protection Apron
- Temperature display controller K type for waste incinerator control case
- Burner Controller RMO88.53C2 for Riello RL34
- Waste Bin 1100Liters
- Riello Burner Contrl Box G10LC
- Baltur Italy BTL20 Oil Burner
- Aeration gate valve(wind valve) for waste incinerators
- Fire proof flange gasket for burner on waste incinerator
- Solar Light Automatic power storage and Automatic light in dark 3200w
- Model TS100(PLC) Waste Incinerator with S.Steel Wet scrubber(spray tower)
- Why use Medical Waste Incinerator?
- Disposal waste incinerator
- medical waste incinerator
- Model: TS5, Medical Waste Incinerator 5-10kgs per hour capacity
- Riello Burner G5 Difuser
- Solenoid on burner for waste incinerator
- Waste Shredder Double Shaft 100-200 Kgs per hour
- The U.S. military’s use of incinerators
- High Aluminum Fire Brick
- How does Tanzania use medical waste incinerators?
- Ecoflam Burner Model MAX30
- G10LC Riello Oil Burner
- Flexible Conduit oil tube for burner on waste incinerators
- Steel Mesh 2.0M Height*20Meter Length
- D.O BURNER NOZZLE TIP 3.0gph
- Circuit board (LMO44.255C2BT) Simens Control Case for burner for waste incinerators
- Burner Contoller LOA24 171B27
- Incinerator for Hosptials
- Baltur BTL20 Burner WINDOW. FLAME(Spare Parts for Burner)
- Top loading door waste incinerator
- QRB4 PhotoCell for burner
- Temperature Controller for incinerator
- Needle Destroyers
- why use mobile type waste incinerator?
- Ignition electrode with 2 leads
- Hiclover Incinerator
- Burner QRB1 Photocell
- Model YD150 Waste Incinerator
- Top Feeding Loading Incinerator Ave 1000kgs per hour Model TS1000(TOP) Oil
- Circuit board LMO44.255C2 Burner Control Box Baltur
- Model YD300 Incinerator 300-500 kg/hour
- Incinerator for Area health Centres
- S.S304 Water Wash Basin
- Syringe Needle Destroyer Needle Incinerator
- High Temperature Protection Gloves
- how to treat ebola medical waste?
- Burner fuel pump AS47B
- Thermal Radiation/High Temperature Apron/Incinerator PPE


Comments are closed